102.4V 12Ah Emergency Backup Lithium Battery Pack RS485 Communication -40℃ Low Temp Resistant Shockproof Stable Structure UPS Emergency Power Supply Battery
| Nominal voltage: | 102.4V | Rated capacity: | 12Ah |
| Charging voltage: | 115.2V | Standard charging current: | 2.4A |
| Maximum charging current: | 6A | Standard discharge current: | 20A |
| Instantaneous discharge current: | 40A | Discharge cut-off voltage: | 80A |
| High Light: | Customizable Low Temperature Battery,UN38.3 Low Temperature Battery,102.4V 12Ah Emergency Backup Power Supply |
||
Product Description:
This 102.4V 12Ah lithium battery pack is developed for industrial emergency standby power systems. It solves common drawbacks of ordinary backup batteries including poor low-temperature performance, weak shock resistance and lack of data communication function. Built with RS485 communication interface, it transmits real-time power and temperature data to host equipment. It supports 20A continuous discharge and 40A instantaneous peak current to meet sudden startup load demands. With reinforced shock-resistant structure and ultra-wide discharge temperature range of -40℃~60℃, it delivers stable power supply for outdoor, cold region and harsh industrial emergency equipment.
Features:
- Ultra-Wide Temperature Adaptability
Stable discharge performance at -40℃ ultra-low temperature, fits alpine, outdoor and low-temperature industrial working environments. - Shockproof Reinforced Structure
Solid internal assembly structure resists vibration and impact, avoiding internal cell damage during transportation and field use. - Strong Instantaneous Discharge Capacity
Supports 40A peak discharge current to handle sudden high startup load of emergency equipment without voltage drop. - RS485 Real-time Data Communication
Real-time bidirectional data transmission between battery and equipment to monitor remaining power and operating status. - Comprehensive Built-in Safety Protection
Complete overcharge, over-discharge and over-current protection to eliminate hidden risks during long standby operation.
Technical Parameters:
| Item | Specification |
|---|---|
| Product Name | 102.4V 12Ah Emergency Backup Lithium Battery |
| Nominal Voltage | 102.4V |
| Rated Capacity | 12Ah |
| Charging Voltage | 115.2V |
| Standard Charge Current | 2.4A |
| Max Charge Current | 6A |
| Standard Discharge Current | 20A |
| Instant Peak Discharge Current | 40A |
| Discharge Cut-off Voltage | 80V |
| Charging Temperature | 0℃ ~ 45℃ |
| Discharge Temperature | -40℃ ~ 60℃ |
| Net Weight | Approx 18Kg |
| Communication Protocol | RS485 |
Applications:
- Outdoor Industrial Equipment Emergency Standby Power
Existing Drawback: Conventional batteries fail to discharge normally under extreme low temperature outdoors.
Solution: Stable discharge at -40℃ ensures continuous power supply for field emergency equipment in cold areas. - Industrial Monitoring UPS Backup Power
Existing Drawback: Batteries without communication function cannot feed power data, triggering unexpected shutdown during monitoring tasks.
Solution: RS485 communication allows equipment to grasp battery status in advance for timely charging arrangement. - Mobile Emergency Rescue Equipment Power Supply
Existing Drawback: Ordinary battery loose structure gets damaged easily by bumping during mobile transportation.
Solution: Shockproof solid structure withstands frequent carrying and vibration for rescue scene use. - Remote Base Station Emergency Power Backup
Existing Drawback: Generic batteries cannot support instantaneous high current when equipment restarts after power failure.
Solution: 40A peak discharge meets instant startup power demand of communication base station equipment.
Customization:
- Adjust voltage, capacity and discharge current parameters to match different emergency equipment models
- Custom RS485 communication logic, pin definition and terminal wiring layout
- Modify casing size, mounting structure and print customer exclusive labels
- Reset internal BMS protection threshold for special industrial standby equipment
- Support small trial batch orders and flexible mass production scheduling
Support and Services:
- Pre-sales technical matching: Engineers provide equipment compatibility verification within 24 hours.
- Full pre-delivery inspection: Each battery undergoes charge-discharge aging and RS485 communication function testing.
- Remote technical guidance for installation, communication debugging and abnormal discharge troubleshooting.
- Provide MSDS, UN38.3 certification documents to smooth global sea and air customs clearance.
- Long-term technical iteration support for updated emergency power equipment models.
Packing and Shipping:
- Packing
Single battery wrapped with thick shockproof foam inside reinforced export cartons. Wooden case packaging is available for bulk orders. All packages are labeled with standard battery hazard marks for customs inspection. - Shipping
Complete dangerous goods certification documents support sea freight, air freight and international cargo delivery. Logistics tracking number will be sent after goods dispatch, and our team will track shipment progress until goods receipt.
FAQ:
Q1: Can this battery work in extremely cold outdoor environments?
A1: It can discharge stably from -40℃ to 60℃, perfectly suitable for alpine and low-temperature field emergency scenarios.
Q2: Is this battery suitable for long-term standby UPS equipment?
A2: Equipped with complete safety protection system and low self-discharge performance, it can be used for long-time standby emergency power supply.
Q3: What charger should I use for this battery pack?
A3: A dedicated 115.2V lithium battery charger is required. Mismatched charging voltage will damage the internal circuit.
Q4: Do you accept customized emergency backup batteries for industrial equipment brands?
A4: Full OEM & ODM customization is available. Contact sales team for bulk quotation and personalized solutions.
Q5: Can this battery support instantaneous high-current startup of industrial equipment?
A5: It supports up to 40A instantaneous discharge current, which fully satisfies the instant high power demand of equipment restart after power failure.